Workshop, tools and materials › Lesson 4 of 18 · 6 min read
Measuring and marking out
A clock part is only useful if it fits. A pivot that is 0.03 mm too large in its hole will bind; one that is 0.1 mm too small will wander and wear. Measuring well means choosing an instrument whose resolution suits the job, using it correctly, and knowing how far to trust the number.
Resolution, accuracy and repeatability
- Resolution is the smallest step an instrument can display (for example 0.01 mm on a digital caliper).
- Accuracy is how close a reading is to the true value. A caliper may display 0.01 mm but be accurate only to ±0.02 or ±0.03 mm.
- Repeatability is how closely repeated measurements agree. This matters most for comparison: if you measure two pivots with the same instrument in the same way, the difference is more trustworthy than either absolute value.
A useful rule is that your instrument should be about ten times finer than the tolerance you need. For a pivot-to-hole fit, where you care about a few hundredths of a millimetre, a micrometer reading to 0.01 mm (or better, 0.001 mm) is appropriate; a ruler is not.
Instruments
| Instrument | Typical resolution | Best for | Notes |
|---|---|---|---|
| Steel rule (150 mm) | 0.5 mm | Rough lengths, laying out | Read at eye level, avoid parallax |
| Vernier or digital caliper | 0.02 / 0.01 mm | External and internal diameters, depth | Use jaws near the root, not the tip, for accuracy; do not use as a clamp or scribe |
| Micrometer (0-25 mm) | 0.01 mm (0.001 mm on vernier or digital types) | Pivots, arbors, wire, plate thickness | Use the ratchet; zero it before use |
| Pivot gauge / pivot calipers | 0.01-0.02 mm | Small pivots on arbors | Slender jaws reach into shoulders |
| Wire and drill gauge | Steps | Identifying drills and wire sizes | Check steps; wire gauges differ by system |
| Feeler gauge | 0.02-0.05 mm steps | End shake, gaps | Never force |
| Thread pitch gauge | Fixed leaves | Identify screw pitch and form | Check metric and Whitworth separately |
| Dividers | Visual | Stepping off lengths, transferring distances | Fine points; set against a rule or a micrometer |
| Engineer's square, straight edge | Visual | Squareness and flatness | Check against light |
Reading a micrometer: worked example
A metric micrometer has a sleeve scale with divisions at 1 mm (above the datum line) and 0.5 mm (below). The thimble has 50 divisions, each worth 0.01 mm, and one full turn advances the spindle 0.5 mm.
- Read the sleeve: the last visible mark below the line is 7.5 mm.
- Read the thimble division aligned with the datum line: 28, meaning 0.28 mm.
- Add: 7.5 + 0.28 = 7.78 mm.
Always close the micrometer on a clean, lightly oiled work surface, turn only the ratchet (not the thimble) to a consistent force, and check the zero before and after.
Sources of error
- Contact force. Squeezing a caliper deforms both instrument and work; use a light, consistent touch. Micrometer ratchets exist for this.
- Parallax. Look straight at the scale. In particular, read steel rules perpendicular to the surface.
- Dirt and burrs. A particle of 0.01 mm changes a reading by 0.01 mm. Wipe jaws and work; deburr before measuring.
- Out of round and taper. Measure a pivot at several points along its length and at 90 degrees round. Pivots worn oval or conical will give different readings.
- Temperature. Steel expands about 12 millionths of its length per degree Celsius, so a 25 mm steel part warmed by 10 degrees grows by about 25 × 12×10⁻⁶ × 10 = 0.003 mm. This is small compared with your reading error, but handling a part for a minute with warm fingers is enough to matter at 0.001 mm.
- Instrument wear and zero error. Check against a gauge block or a known-size drill shank.
- Abbe error. Measure with the part near the root of the caliper jaws, close to the scale, where the instrument is most accurate.
Marking out
Marking out transfers the drawing, or the position copied from the old part, to the metal. Good clock marking out is fine, clear and accurate.
Tools
- Scriber: a hardened point, sharpened to a fine needle. The line should be fine, not scratched deep.
- Engineer's blue (marking blue, a dye) on bright metal gives a clear contrast; a marker pen gives a thicker line but is easier to see. For brass, a thin layer of marking blue also reveals scribed lines clearly.
- Centre punch: a light tap leaves a dimple that guides a drill. A 60 degree point is used for marking and a 90 degree point for starting larger drills.
- Dividers and odd-leg calipers to scribe parallel lines and find centres.
- Surface plate or flat plate and a scribing block (height gauge) for lines at a set height. A thick plate of float glass, or a piece of ground steel, makes a workable flat reference.
- Engineer's square to check that edges are perpendicular.
Procedure for marking a hole centre
- Clean and, if needed, blue the surface.
- Scribe two lines intersecting at the centre, from a datum edge, measured from the edge with calipers or dividers.
- Check with a 10× loupe that the lines cross cleanly.
- Place the point of a light centre punch on the crossing, in the right-angle of the lines, tap once, and recheck. If the punch mark has slipped, tilt the punch towards the true centre and tap again to draw it across.
- Scribe the circle with dividers (radius from the dimension) to give a visual check of the hole position after drilling.
Working from the old part
For replacement parts, most positions come from the original or from a mating part. Methods include:
- Copying through the hole. Clamp the old part on the new blank and scribe through its holes.
- Pricking through. Use a pricker to transfer holes in a plate to a second plate.
- Stepped dividers. Set the dividers on the old part and mark the new blank on a datum edge.
- Photograph on a rule as a record of position and orientation.
Common mistakes
- Using a caliper at its resolution limit and treating 0.01 as accurate.
- Measuring warm parts straight from the lathe or after polishing.
- Scribing deep lines in finished surfaces.
- Centre-punching a thin, unsupported plate, which dishes it. Support the plate on a flat block.
Sources
- General metrology and workshop practice; no single web source was used for this lesson. The thermal expansion coefficient for steel (about 12 × 10⁻⁶ per °C) is a standard textbook value.
Get new lessons by email
Free, practical clock repair lessons for beginners. No spam, unsubscribe any time.