The physics and engineering of clocks › Lesson 1 of 10 · 8 min read
Time, frequency and accuracy
Every clock is a counter driven by an oscillator. The oscillator (pendulum or balance) sets how fast time passes on the dial, and the gear train simply counts its swings and displays the total. A clockmaker who can state error precisely, and convert between the units in which it is quoted, can compare any two clocks, any two repairs and any two adjustments on equal terms. This lesson fixes the vocabulary used in every later lesson.
Period, frequency and beat
An oscillator repeats the same motion again and again. The period T is the time for one complete cycle (out and back to the starting point) and the frequency f is the number of cycles per second.
f = 1 ÷ T T = 1 ÷ f unit of f: hertz (Hz) = cycles per second
Clockmakers rarely talk in hertz. They count beats (also called vibrations or, in older English, "ticks"). One beat is one swing from one extreme to the other, which is half a cycle. A beat is the interval between two successive escapement impulses, so the tick-tock you hear is two beats. Rates are quoted as beats per hour (bph, or vph for vibrations per hour; the two are the same thing).
beats per hour = 7200 × f (f in Hz) f = bph ÷ 7200
The factor 7200 is 3600 seconds per hour multiplied by 2 beats per cycle. A common source of confusion is that watch literature sometimes quotes the beat rate as "Hz" (for example "4 Hz" for 28,800 bph). That usage means 4 beats per second counted as full cycles of the balance, so check which is meant before calculating.
| Beats per hour | Beats per second | Frequency f (Hz) | Period T (s) | Typical use |
|---|---|---|---|---|
| 1,800 | 0.5 | 0.25 | 4.0 | Very long pendulums of about 4 m (some turret clocks and the largest tower clocks) |
| 2,400 | 0.67 | 0.33 | 3.0 | Some large regulators and early longcase clocks |
| 3,600 | 1 | 0.5 | 2.0 | Seconds pendulum: longcase and regulator |
| 4,800 | 1.33 | 0.67 | 1.5 | Bracket and some longcase clocks |
| 7,200 | 2 | 1.0 | 1.0 | Mantel, bracket, many French clocks |
| 9,000 | 2.5 | 1.25 | 0.8 | Some American shelf and German clocks |
| 14,400 | 4 | 2.0 | 0.5 | Short-pendulum and older platform clocks, alarm clocks |
| 18,000 | 5 | 2.5 | 0.4 | Carriage clocks, older and pocket watches |
| 21,600 | 6 | 3.0 | 0.333 | Watches of the 1950s to 1970s |
| 28,800 | 8 | 4.0 | 0.25 | Modern mechanical watches |
| 36,000 | 10 | 5.0 | 0.2 | High-beat watches |
Accuracy, rate and stability
Three ideas are often blurred together, and keeping them apart is half the skill of regulating a clock.
- Rate is how fast the clock is going compared with true time, usually expressed as seconds gained or lost per day. A clock can have a large rate and still be a very good clock.
- Accuracy is how close the clock's displayed time (or rate) is to the true value. It is what the customer notices.
- Stability (or precision) is how much the rate changes from day to day. A clock losing exactly 20 s every day is perfectly stable and can be corrected by moving the rating nut. A clock that varies between 0 and -20 s on different days cannot be fixed by adjusting the rate, only by finding and removing the causes of the variation.
This is why the later lessons spend so much time on what changes the rate (amplitude, temperature, drive force, friction) rather than on how to set it. Setting the rate is easy. Making it stay set is the craft.
Expressing error three ways
1. Seconds per day (s/d). The standard working unit. Convention: positive means gaining (fast), negative means losing (slow). Always state the sign. Timing machines follow this convention (positive means the watch runs fast).
2. Fractional error. If a clock shows a time interval Tclock while the true interval is Ttrue, then
G = (Tclock − Ttrue) ÷ Ttrue
G is a pure number. Rate in s/day = G × 86,400. A timing-machine manufacturer defines rate in just this way, noting that a few older texts divide by the clock's own interval instead; the difference is negligible for the small errors of a working clock.
3. Parts per million (ppm). G × 1,000,000. Electronics and quartz crystals are always quoted in ppm. One ppm is one microsecond of error per second.
Because there are 86,400 seconds in a day, the conversion is neat:
1 ppm = 0.0864 s/day 1 s/day = 11.57 ppm
| Error | ppm | Per day | Per week | Per month (30 d) | Per year |
|---|---|---|---|---|---|
| 1 ppm | 1 | 0.086 s | 0.60 s | 2.6 s | 31.6 s |
| 6 ppm (good quartz) | 6 | 0.52 s | 3.6 s | 15.5 s | 3.2 min |
| 1 s/day | 11.6 | 1 s | 7 s | 30 s | 6.1 min |
| 10 s/day | 115.7 | 10 s | 70 s | 5 min | 1.0 h |
| 1 min/week | 99.2 | 8.6 s | 60 s | 4.3 min | 52 min |
| 1% (a very sick clock) | 10,000 | 14.4 min | 1.7 h | 7.2 h | 3.7 days |
Worked example 1: rating from a comparison
A longcase clock is set exactly to a reference time signal at 20:00 on Monday. At 20:00 the following Monday (168 hours = 604,800 s of true time) it reads 17 s behind. G = −17 ÷ 604,800 = −2.81 × 10⁻⁵, which is −28.1 ppm. Rate = −28.1 × 0.0864 = −2.43 s/day (slow). In the language of the next lessons you would then need to shorten the pendulum slightly, by a fraction ΔL/L = 2 × 2.43 ÷ 86,400 = 5.6 × 10⁻⁵, about 0.056 mm on a 994 mm pendulum.
Worked example 2: from beat rate to the train
A carriage clock balance runs at 18,000 bph. Per day that is 18,000 × 24 = 432,000 beats. If the escape wheel has 15 teeth and the lever escapement releases two beats per tooth, the escape wheel turns 432,000 ÷ 30 = 14,400 times in a day, which is 10 turns a minute. Counting beats is how you check a train: the next lesson shows how to do it from the wheel counts.
Worked example 3: effect of a fault on the dial
A mechanical clock gains 3 minutes in a week. That is 180 s ÷ 604,800 s = 297.6 ppm, or 25.7 s/day. The oscillator is running 0.030% fast. If the oscillator is a seconds pendulum of effective length 0.9936 m, the pendulum is too short by ΔL = 2 × 0.000298 × 993.6 mm ≈ 0.59 mm.
What accuracy do real timekeepers reach?
Benchmarks help you judge what is realistic. The figures below are either calculated from the definitions above or are typical values from the references listed under Sources; the "workshop" figures are typical practice, varies, and are not standards.
| Timekeeper | Typical error | Comment |
|---|---|---|
| Standard 32.768 kHz watch quartz | Typically of the order of 5 to 10 ppm (roughly 15 s a month) at room temperature; the specification varies by maker | Crystal is a tuning fork cut to 2¹⁵ Hz; error grows parabolically away from its turnover temperature (typically in the mid-twenties °C), by roughly −0.035 ppm per °C squared; typical values, vary between crystals |
| Good pendulum clock, small constant arc | Seconds per week | Workshop norm for a well-adjusted regulator; a sound domestic recoil-anchor longcase is usually within about a minute a week |
| Mechanical wristwatch | A few s/day | Varies with position, wind, temperature and age of oil |
| Riefler precision regulator (1898) | A few hundredths of a second a day claimed by the maker; typical practice, varies, and not an independent measurement | Invar pendulum, temperature-compensated, near-constant arc |
| Shortt master pendulum in vacuum | Within a few seconds a year (Royal Museums Greenwich) | Free pendulum in a partial vacuum, impulsed once every 30 s; its Q is very high compared with an ordinary clock pendulum (quoted figures vary) |
Check your work
- Always record both the time interval and the error when you quote a rate. "Loses 10 seconds" means nothing; "loses 10 seconds in 24 hours" is a rate.
- Never rate a clock over less than about an hour by eye, and prefer a full day or more. Lesson 10 (metrology) shows how reading error divides by the length of the test.
- When you change something (a nut, a hairspring length), log the rate before and after under the same conditions.
Common mistakes
- Mixing up beats and cycles: a seconds pendulum has a period of 2 s, not 1 s. Its beat is 1 s.
- Forgetting the sign of the rate. A change of +3 s/d applied to a clock that is already at +2 s/d makes it worse.
- Confusing a rate error with instability. If the rate changes with the seasons you cannot fix it with the rating nut.
- Quoting 1 ppm as 1 s/day. It is 0.0864 s/day.
Sources
- ISO 3159:2009, Timekeeping instruments: wrist-chronometers with spring balance oscillator (International Organization for Standardization): rate and test definitions
- J. R. Vig, Quartz crystal resonators and oscillators for frequency control and timing applications: a tutorial (US Army LABCOM report SLCET-TR-88-1, rev. 5.2, 1992): frequency-temperature behaviour of quartz resonators
- Shortt Free Pendulum System No 16 (Royal Museums Greenwich): free pendulum in partial vacuum, accuracy within a few seconds a year
- An astronomical regulator by Siegmund Riefler, number 152, 1905 (Royal Museums Greenwich)
- The International System of Units (SI), Appendix 1, decisions of the CGPM (BIPM text, reproduced as NIST SP 330): standard acceleration of gravity 9.80665 m/s², adopted by the 3rd CGPM in 1901
- A. L. Rawlings, The Science of Clocks and Watches, 3rd edition, British Horological Institute, 1993 (first published by Pitman, 1944).
- R. J. Matthys, Accurate Clock Pendulums, Oxford University Press, 2004.
- Note: the temperature coefficient and room-temperature accuracy quoted for watch quartz are typical figures, not a standard; they vary by crystal and manufacturer.