The physics and engineering of clocks › Lesson 10 of 10 · 12 min read
Metrology for clockmakers: measuring, uncertainty and rating a clock
Everything in the earlier lessons ends in a number: a pivot diameter, a centre distance, a rate in seconds a day. A number is only useful if you know how far to trust it. Clockwork is small, and the differences that matter are small: a hundredth of a millimetre on a pivot, a tenth of a second in a day. This lesson covers the measuring instruments a clockmaker uses, how to read them, how to estimate uncertainty without a statistics course and how to rate a clock properly.
The instruments
| Instrument | Resolution (smallest reading) | Good for | Not good for |
|---|---|---|---|
| Steel rule | about 0.5 mm | Plate sizes, rough pendulum lengths, drops | Anything fitted |
| Vernier caliper | 0.02 mm (some 0.05 mm) | Wheel diameters, plate thickness, centre distances, depth of holes | Pivots to a hundredth |
| Digital caliper | 0.01 mm | As vernier; quick; zero anywhere | Resolution is not accuracy: check against a known size |
| Micrometer (metric) | 0.01 mm (thimble) | Pivots, arbors, wire, spring thickness, wheel thickness | Soft or thin work if over-tightened |
| Vernier micrometer | 0.001 mm | Fine pivots and gauge work | Over-reading: see uncertainty below |
| Dial gauge (plunger indicator) | 0.01 mm | End-shake, flatness, runout of wheels and arbors | Tiny forces |
| Dial test indicator (lever type) | 0.002 to 0.001 mm | Centring work in a lathe, pivot and bush alignment | Large movements (short range) |
Two rules of thumb from engineering practice: use an instrument whose smallest reading is about ten times finer than the tolerance you are working to (so for a 25.5 mm dimension a 0.01 or 0.02 mm instrument; for 25.50 mm a 0.001 or 0.002 mm one), and measurements around 0.2 mm (0.010") or less generally need a precision instrument rather than a rule.
Reading the instruments
Vernier caliper (0.02 mm)
- Close the jaws against a light: there should be no light gap and the scale should read zero.
- Read the main scale value just to the left of the vernier's zero mark. Say 3 mm.
- Find the vernier line that lines up exactly with a line on the main scale. If it is the line marked 6, that adds 0.60 mm.
- Add: 3 + 0.60 = 3.60 mm.
A 0.02 mm vernier has 50 divisions covering 49 mm, so each vernier division is 0.02 mm shorter than a main scale division; each step along the vernier adds 0.02 mm.
Micrometer (0.01 mm)
- Clean the anvil and spindle faces and the work. Close the spindle with the ratchet or friction thimble (never the barrel), and check the reading is zero. If not, note the zero error and correct every reading.
- Open it, place the work and close gently with the ratchet until it clicks. The ratchet limits the force so every reading uses about the same pressure.
- Read the sleeve: whole millimetres above the datum line and half-millimetres below it. Then read the thimble, where each division is 0.01 mm (50 divisions to one revolution of 0.5 mm).
- Add the two. For example, sleeve showing 6 mm and the half-millimetre line, thimble reading 0.28: 6.5 + 0.28 = 6.78 mm.
Dial gauge
A plunger dial gauge shows how far the plunger moves, usually 0.01 mm a division. Mount it on a stand, zero it on the part and move the part. Total indicated runout (TIR) is the full swing of the needle as a wheel is rotated: it tells you how far a wheel is out of true or an arbor is bent. The same gauge measures end-shake of an arbor (push and pull the arbor along its axis) and flatness of a plate.
Worked example. A 60-tooth third wheel with module 0.65 mm has a dial gauge TIR of 0.05 mm at the rim. The wheel's radius at the teeth varies by ± 0.025 mm as it turns, which is 3.8% of a module of tooth engagement. This is enough to make the depthing feel different at different points of the revolution, and to cause noticeable rubbing on a tooth. Correct by re-centring the wheel (checking arbor and wheel seating).
Good measuring habits
- Clean everything. A dust particle or an oil film on an anvil can be 0.01 mm thick.
- Use the same pressure every time (ratchet on a micrometer; light, consistent hand pressure on calipers).
- Measure at several places and orientations: pivots are often out of round or tapered. Report the largest and smallest.
- Let the part and instrument reach room temperature before you trust a reading: steel expands by 11.5 ppm per °C, so a 25 mm piece 5 °C warmer than the instrument is 0.0014 mm longer. This is negligible for a clock but not for a gauge-block calibration.
- Line the measurement up with the scale. Wherever possible, have the part being measured on the same line as the scale (Abbe's principle); a caliper measured with the work deep in the jaws and the jaws tilted reads high.
- Do not "feel" a pivot with the jaws closed on a shoulder; measure the pivot diameter itself, and the shoulder separately.
Uncertainty: how far to trust a reading
An honest measurement is stated as value ± uncertainty. A simple, reliable way to estimate it combines the main contributions in quadrature (square, add, square root), the standard method of the Guide to the expression of uncertainty in measurement (JCGM 100):
- Resolution. A reading can be off by up to half the smallest division. The standard uncertainty is the smallest division divided by √12 (about 3.5), the standard result for a rectangular distribution.
- Repeatability. Measure several times and compute the sample standard deviation s. The uncertainty of the mean of n readings is s ÷ √n.
- Instrument error. From calibration against a gauge block or the maker's specification. If it is ± a, treat it as a limit and divide by √3.
- Combine: u = √(u₁² + u₂² + u₃²). Quote an expanded uncertainty of 2 × u for about 95% confidence.
Worked example: a pivot
Five micrometer readings of a pivot: 1.99, 2.00, 1.99, 2.00, 2.00 mm. Mean = 1.996 mm; s = 0.0055 mm.
- Resolution: 0.01 ÷ √12 = 0.0029 mm.
- Repeatability: 0.0055 ÷ √5 = 0.0024 mm.
- Instrument error: say the micrometer checks to ±0.004 mm against a gauge block; 0.004 ÷ √3 = 0.0023 mm.
- Combined: u = √(0.0029² + 0.0024² + 0.0023²) = 0.0044 mm. Expanded (k = 2): 0.0089 mm.
Report 2.00 ± 0.01 mm. A student who writes 1.996 mm is claiming a precision of a thousandth that the measurement does not have. Reading to 0.01 mm is the practical limit of a standard micrometer in a workshop, and the uncertainty is about the same size as one division. Clock practice demands just this level: judging a pivot to a hundredth of a millimetre, a bush to a hundredth, an arbor shake by feel and by dial gauge.
Rating a clock
To rate a clock is to measure how fast it is going. Rate was defined in Lesson 1 as the fractional error times 86,400, in seconds a day, positive for gaining. There are three ways to get it.
1. Compare with a reference over time
Note the clock's time against a reference at the start, and again after an interval. Rate = (error change) ÷ (interval), expressed per day. The reference must be much better than the clock: a quartz clock set from a network time signal, a radio-controlled clock or a phone time display synchronised to the network are all good to a small fraction of a second.
The problem is reading error. If you can read the clock to ±0.1 s, then a rate calculated from two readings is uncertain by about √2 × 0.1 s divided by the interval:
| Interval between readings | Rate uncertainty (reading error ±0.1 s) |
|---|---|
| 1 hour | about 3.4 s/day |
| 1 day | about 0.14 s/day |
| 7 days | about 0.02 s/day |
The same arithmetic applies to any method that can resolve only one beat: at 4 beats a second a reading uncertainty of half a beat (0.125 s) gives about 3 s/day over one hour and about 0.125 s/day over 24 hours. The lesson: a short test cannot reveal a small rate. To resolve one second a day you need at least a day and good reading technique.
2. Timing machine (timegrapher)
A timing machine listens to the ticks (with a microphone or contact sensor) and measures the time between them against its own quartz clock. It reports:
- Rate in s/day: the machine computes the rate of the tick and the tock separately and averages them, which removes the effect of beat error.
- Beat error in milliseconds: half the difference between the two intervals, tick-to-tock and tock-to-tick.
- Amplitude in degrees, derived from the time between the unlocking and drop sounds, the lift angle of the escapement and the beat rate. For a watch lever this is typically taken as about 50° (varies by calibre); if the lift angle entered is wrong, so is the amplitude. In pendulum clocks amplitude is better read directly from a scale behind the bob.
Typical practice for watches, varies by machine and maker: let the movement run for about 20 minutes before testing, let each position settle for about 20 s and measure for at least 40 s in each position. Positions matter because gravity acts differently on the balance in each; the common six are dial up, dial down and four vertical ones (crown down, left, up and right). The machine's reading also changes with temperature, magnetic field, air pressure and the state of the oil, so a good reading is only part of the story.
Since a timing machine takes seconds, not days, it can show a rate of 3 s/day only to a resolution set by how many beats it averages: the same arithmetic as above applies. Use it to find faults and compare before-and-after values; use a long reference comparison for the final rate.
3. Phone apps
Many phones can run a timing app that listens through the microphone and does what a timing machine does. They are good for beat error, for finding whether a clock is badly out of beat, and for rough rates. Limits:
- The microphone picks up room noise and the ticks of other clocks. Work in a quiet room and hold the phone steady, close to the movement.
- The app's timing relies on the phone's audio sampling clock, a quartz oscillator, probably accurate to tens of parts per million (a few seconds a day). Phone makers do not generally guarantee it, and it varies between models. Check the app against a known reference, for example a quartz clock or a watch whose rate you know, before using it to regulate a good clock.
- Pendulum clocks tick at 1 beat/s or slower; apps designed for watches may not handle them. Choose the beat rate manually.
Rating in practice: a worked log
Wind a longcase fully, put it in beat, leave it a day to settle and then read it each day at the same time against a network-synchronised phone clock. Record also the room temperature and the amplitude.
| Day | 1 | 2 | 3 | 4 | 5 | 6 | 7 |
|---|---|---|---|---|---|---|---|
| Daily rate (s/day) | −4.1 | −3.8 | −4.5 | −3.6 | −4.2 | −3.9 | −4.3 |
- Mean rate: −4.06 s/day. Sample standard deviation: 0.31 s/day. Standard error of the mean over 7 days: 0.12 s/day.
- The scatter of 0.3 s/day is the clock's day-to-day stability (and also includes your reading errors). You cannot regulate it better than that.
- Required correction: raise the bob by ΔL = 4.06 ÷ 43,200 × 993.6 mm = 0.093 mm. With an 0.8 mm-pitch rating nut that is 0.117 of a turn, about 42°.
- Make the adjustment, wait a day for things to settle, then log another week. Expect a new mean near 0 and the same 0.3 s/day scatter.
Never adjust more than once between logs: you will not know which change did what. If the mean drifts with the season, you are seeing temperature (Lesson 9); if it drifts as the weights fall, you are seeing drive force (Lesson 2); if it drifts after a few weeks and the amplitude is dropping, the oil is going off (Lesson 5).
Check your work
- State every measurement with the instrument and the uncertainty: "2.00 ± 0.01 mm (micrometer)".
- Zero every instrument before use and note any zero error.
- For a rate, state the interval: "−4.1 s/day over 24 h" and record temperature and amplitude.
- Before adjusting a pendulum, calculate the rate change you expect (Lesson 6); afterwards, compare with what you got.
Common mistakes
- Reading a digital caliper to 0.01 mm and believing every digit. Resolution is not accuracy.
- Forcing the micrometer spindle by hand: pressure compresses soft brass and varies from reading to reading. Use the ratchet.
- Rating a clock over ten minutes and moving the nut: the reading error swamps the rate.
- Changing several things between ratings (cleaning, levelling, nut) and then not knowing what did what.
- Trusting a phone app's amplitude readout for a pendulum clock without checking it against a scale.
Sources
- JCGM 100:2008, Evaluation of measurement data: Guide to the expression of uncertainty in measurement (BIPM/JCGM): combining standard uncertainties in quadrature, rectangular-distribution divisors, expanded uncertainty
- Introduction to Machining, Module 5: Measuring tools (Department of Mechanical and Industrial Engineering, University of Toronto): reading verniers and micrometers, the ten-to-one rule
- ISO 3159:2009, Timekeeping instruments: wrist-chronometers with spring balance oscillator (International Organization for Standardization): rate and test definitions
- R. J. Corruccini and J. J. Gniewek, Thermal expansion of technical solids at low temperatures, NBS Monograph 29 (US National Bureau of Standards, 1961): room-temperature expansion of aluminium, zinc and steels
- Note: the 11.5 ppm per °C expansion of steel used in the temperature note is a typical handbook value (see Smithells), and varies by steel.
- E. A. Brandes and G. B. Brook (eds), Smithells Metals Reference Book, 7th edition, Butterworth-Heinemann, 1992 (thermal expansion and elastic properties of metals).
- A. L. Rawlings, The Science of Clocks and Watches, 3rd edition, British Horological Institute, 1993 (first published by Pitman, 1944).
Get new lessons by email
Free, practical clock repair lessons for beginners. No spam, unsubscribe any time.